Part No. : 184K0000-7 | Alternate P/N : 184K00007 | Manufacturer : Drs Sustainment Systems Inc |
CAGE Code : 4NG64 | Item Name : Air Conditioner | FSC : 4120 Air Conditioning Equipment |
NSN : 4120-01-608-7504 |
You can send a request for quote for p/n 184K0000-7 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Drs Sustainment Systems Inc (CAGE Code 4NG64). The description of it is Air Conditioner. The national stock number associated with this part is NSN 4120016087504. This part belongs to FSC Air Conditioning Equipment part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 184K0000-7 part requirements.
Required fields compulsory *
MRC | Criteria | Characteristic |
---|---|---|
ATJK | Power Source | ELECTRIC MOTOR |
ABMK | Overall Width | 35.0 INCHES NOMINAL |
FAAZ | Phase | THREE |
CXCY | Part Name Assigned By Controlling Agency | ENVIRONMENTAL CONTROL UNIT (ECU) |
AGAV | End Item Identification | 17-3-3000, 5410-01-592-9464 |
CYKM | Heating Capacity In Btu Per Hour | 33.0 NOMINAL |
ABHP | Overall Length | 46.5 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AAXX | Mounting Type | TRUCK |
CYJE | Cooling Capacity In Btu Per Hour | 60.0 NOMINAL |
ALCD | Usage Design | HEAT, VENT AND COOL |
ABKW | Overall Height | 42.0 INCHES NOMINAL |
FEAT | Special Features | COLOR - TAN; COOLING CAPACITY MINIMUM60,000 BTU/HR AT PLUS 125 DEGREE F; HEATING CAPACITY MINIMUM 33,000 BTU/HR AT NEGITIVE 40 DEGREES F; ELECTRICAL POWER NOT TO EXCEED 10.8 KW IN A 208 VAC, 3-PHASE, 5-WIRE CONFIGURATION, WITH SOFT START; OPERATING TEMP -40 DEGREE F TO +125 DEGREE F; STORAGE TEMP -40 DEGREE F TO +160DEGREE F; HUMIDITY DAILY EXPOSURE OF UP TO 97% RH AND EXPOSURE TO 100% RH WITH CONDENSATION; NO DEGRADATION FOR CORROSION, SOLAR LOAD, WIND LOAD, SNOW LOAD, DUST/SAND, CHEMICAL AND BIOLOGICAL EXPOSURE; CHEMICAL AND BIOLOGICAL PROTECTION - NO SUCTION OF CB CONTAMINATED AIR INTO THE EVAPORATOR SECTION AIR STREAM; HIGH ALTITUDE EMP; SOUND LEVEL NOT TO EXCEED 72DB(A) AT IM FROM UNIT;ELECTROMAGNETIC INTERFERENC PER MIL-STD 461E; DIAGNOSTIC EQUIP TMDE FOUND IN DA PAMPHLET 700-21-1; NEAR STRIKE SURVIVAL - DNOT DAMAGED BY 90TH PERCENTILE LIGHTNING STRIKE (NEAR-STRIKE EVNIRONMENT); |
AZQK | Weight | 530.0 POUNDS MAXIMUM |