Part No. : TEF126M1100 Manufacturer : General Electric Co CAGE Code : 60969
Item Name : Circuit Breaker FSC : 5925 Circuit Breakers NSN : 5925-00-464-0666

You can send a request for quote for p/n TEF126M1100 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by General Electric Co (CAGE Code 60969). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925004640666. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with TEF126M1100 part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Characteristics Data of NSN 5925-00-464-0666, 5925004640666

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH6.312 INCHES NOMINAL
ABKWOVERALL HEIGHT3.375 INCHES NOMINAL
ABMKOVERALL WIDTH2.750 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODDEION
CBBLFEATURES PROVIDEDADJUSTABLE TRIP RELEASE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE100.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS600.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS10000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP W/SEPARATE RESET
CPSFADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS+480.0/+1000.0 AC ALL LOCATIONS
FEATSPECIAL FEATURESMOUNTING METHOD IS UNTHREADED HOLE
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
PRMTPRECIOUS MATERIALSILVER
TTQYTERMINAL TYPE AND QUANTITY4 SCREW