Part No. : THED126050WL Manufacturer : General Electric Co CAGE Code : 60969
Item Name : Circuit Breaker FSC : 5925 Circuit Breakers NSN : 5925-00-542-9637

You can send a request for quote for p/n THED126050WL to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by General Electric Co (CAGE Code 60969). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925005429637. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with THED126050WL part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Information for Part Number THED126050WL with NSN 5925-00-542-9637, 5925005429637

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-542-9637

Item Description:

Circuit Breaker

59250054296370P
CIICHCCESDPMICCriticalityENAC
U U
Part NumberISCRNVCRNCCHCCMSDSSADC
Thed126050wl595

Characteristics Data of NSN 5925-00-542-9637, 5925005429637

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ADAQBODY LENGTH6.312 INCHES NOMINAL
ADATBODY WIDTH4.125 INCHES NOMINAL
ADAUBODY HEIGHT3.188 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH5.250 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.375 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.880 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.380 INCHES NOMINAL
AJECBOSS HEIGHT0.125 INCHES NOMINAL
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS600.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS18000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODTHERMAL-MAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT95.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 250.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
CRCFTRIP RELEASE AMBIENT TEMP RATING40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
TTQYTERMINAL TYPE AND QUANTITY6 COMPRESSION