Part No. : E00798 | Manufacturer : Manitex Liftking Ulc | CAGE Code : 38490 |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers | NSN : 5925-01-144-1230 |
You can send a request for quote for p/n E00798 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Manitex Liftking Ulc (CAGE Code 38490). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925011441230. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with E00798 part requirements.
Required fields compulsory *
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-144-1230 Item Description: Circuit Breaker | 5925 | 011441230 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
E00798 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 1.235 INCHES MINIMUM AND 1.265 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.425 INCHES MINIMUM AND 0.455 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AGAV | END ITEM IDENTIFICATION | 2320-01-121-2102 |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 12.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |
Please contact us to receive an instant quotation