Part No. : 214-0006-009 | Alternate P/N : 2140006009 | Manufacturer : Rockwell Collins Inc |
CAGE Code : 95105 | Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
NSN : 5925-01-050-9030 |
You can send a request for quote for p/n 214-0006-009 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Rockwell Collins Inc (CAGE Code 95105). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925010509030. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 214-0006-009 part requirements.
Required fields compulsory *
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-050-9030 Item Description: Circuit Breaker | 5925 | 010509030 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
214-0006-009 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 3 COMPRESSION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.250 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
MRC | Decoded Requirement | Clear Text Reply |
AXHR | Mounting Facility Type And Quantity | 6 TERMINAL |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.230 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 3 CLIP AND |
ADAQ | Body Length | 6.250 INCHES NOMINAL |
ADAU | Body Height | 2.580 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 240.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE TWO |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
Please contact us to receive an instant quotation