831-551-015 (Circuit Breaker) by Aeg Corp - Request a Quote Now

Part No. : 831-551-015 Alternate P/N : 831551015 Manufacturer : Aeg Corp
CAGE Code : 24972 Item Name : Circuit Breaker FSC : 5925 Circuit Breakers
NSN : 5925-01-240-7050

You can send a request for quote for p/n 831-551-015 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Aeg Corp (CAGE Code 24972). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925012407050. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 831-551-015 part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Information for Part Number 831-551-015 with NSN 5925-01-240-7050, 5925012407050

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-240-7050

Item Description:

Circuit Breaker

59250124070500P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
831-551-015 23

Characteristics Data of NSN 5925-01-240-7050, 5925012407050

MRCCriteriaCharacteristic
AKPXPole Quantity2
CPRFOperating Voltage Type And Rating Per Pole In Volts220.0 AC ALL LOCATIONS
MRCDecoded RequirementClear Text Reply
FREQFrequency In Hertz60.0 ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps6000.0 AC ALL LOCATIONS
CPRJTrip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 ALL LOCATIONS
CPRQReset MethodMANUAL
CPRTManual Actuator Type And Quantity2 TOGGLE
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
ADATBody Width15.6 MILLIMETERS NOMINAL
ADTVCase MaterialPLASTIC
TTQYTerminal Type And Quantity4 COMPRESSION
ADAQBody Length77.0 MILLIMETERS NOMINAL
ADAUBody Height61.0 MILLIMETERS NOMINAL
CPLMMaximum Continuous Load Current Rating Per Pole25.0 AMPERES AC ALL LOCATIONS
AAQLBody StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
AEBQCenter To Center Distance Between Terminals Parallel To Width7.8 MILLIMETERS NOMINAL
CPRLTrip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
AGAVEnd Item Identification2815-99-739-4949ENGINE,DIESEL,MODEL 16RP200M ONBOARD 110 FT COAST GUARD VESSELS
CPRWActuator FunctionTRIP-RESET
ASAP Semiconductor's Certifications and Memberships