PP400-6-4 (Circuit Breaker) by Bauer Inc - Request a Quote Now

Part No. : PP400-6-4 Alternate P/N : PP40064 Manufacturer : Bauer Inc
CAGE Code : 70882 Item Name : Circuit Breaker FSC : 5925 Circuit Breakers
NSN : 5925-00-620-5854

You can send a request for quote for p/n PP400-6-4 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Bauer Inc (CAGE Code 70882). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925006205854. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with PP400-6-4 part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Information for Part Number PP400-6-4 with NSN 5925-00-620-5854, 5925006205854

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-620-5854

Item Description:

Circuit Breaker

59250062058540P
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
Pp400-6-4225

Characteristics Data of NSN 5925-00-620-5854, 5925006205854

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ADAQBODY LENGTH5.000 INCHES NOMINAL
ADATBODY WIDTH4.750 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.625 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.688 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.250 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
AJECBOSS HEIGHT0.312 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE4.625 INCHES NOMINAL
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
CMLPTHREAD QUANTITY PER INCH20
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC ALL LOCATIONS AND 50.0 AMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS125.0 AC ALL LOCATIONS AND 125.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS10000.0 AC ALL LOCATIONS AND 5000.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODTHERMAL-MAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CQJXNOMINAL THREAD SIZE0.250 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 210.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATING50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY6 COMPRESSION
ASAP Semiconductor's Certifications and Memberships