Part No. : PS2-2457-5 | Alternate P/N : PS224575 | Manufacturer : British Sarozal Ltd |
CAGE Code : K0577 | Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
NSN : 5925-00-075-7892 |
You can send a request for quote for p/n PS2-2457-5 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by British Sarozal Ltd (CAGE Code K0577). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925000757892. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with PS2-2457-5 part requirements.
Required fields compulsory *
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-075-7892 Item Description: Circuit Breaker | 5925 | 000757892 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ps2-2457-5 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | EXPLOSION PROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
AAQL | Body Style | SINGLE POLE TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AKPX | Pole Quantity | 1 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
AJEC | Boss Height | 0.125 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
THSD | Thread Series Designator | UNF |
CQJX | Nominal Thread Size | 0.190 INCHES |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
AJWX | Mounting Surface To Terminal End Distance | 1.359 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 75.000 NOMINAL AT 100 PCT SINGLE LOCATION AND 10.000 MINIMUM AT 125 PCT SINGLE LOCATION AND 75.000 MAXIMUM AT 125 PCT SINGLE LOCATION AND 5.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 0.700 MINIMUM AT 400 PCT SINGLE LOCATION AND 2.000 MAXIMUM AT 400 PCT SINGLE LOCATION AND 0.500 MINIMUM AT 500 PCT SINGLE LOCATION AND 1.000 MAXIMUM AT 500 PCT SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 32 |
CPRP | Ultimate Trip Time Per Pole In Seconds | 10.000 MINIMUM SINGLE LOCATION AND 75.000 MAXIMUM SINGLE LOCATION |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
Please contact us to receive an instant quotation