Part No. : 2221426 | Manufacturer : Detroit Switch Corp | CAGE Code : 19278 |
Item Name : Switch Thermostatic | FSC : 5930 Switches | NSN : 5930-00-827-2001 |
You can send a request for quote for p/n 2221426 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Detroit Switch Corp (CAGE Code 19278). The description of it is Switch Thermostatic. The national stock number associated with this part is NSN 5930008272001. This part belongs to FSC Switches part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 2221426 part requirements.
Required fields compulsory *
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-827-2001 Item Description: Switch Thermostatic | 5930 | 008272001 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2221426 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 5.906 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.687 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 840.000 INCHES NOMINAL |
AEVU | BULB LENGTH | 39.500 INCHES NOMINAL |
AEVV | BULB DIAMETER | 1.125 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTHF | CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00/+60.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
FEAT | SPECIAL FEATURES | FHREE 9/32 IN. MTG HOLES,TWO HOLES ON TOP SPACED 1-13/64 IN. ON EA SIDE OF CENTERLINE,ONE HOLE ON BOTTOM SPACED 35/64 IN. TO LEFT OF CENTERLINE,CENTER OF TOP HOLES TO CENTER OF BOTTOM HOLE 3-9/32 IN. |
AWTN | OPERATING TEMP RATING | -100.0 DEG FAHRENHEIT MINIMUM AND 150.0 DEG FAHRENHEIT MAXIMUM |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |