AM3-2353-13 (Circuit Breaker) by Eaton Corporation - Request a Quote Now

Part No. : AM3-2353-13 Alternate P/N : AM3235313 Manufacturer : Eaton Corporation
CAGE Code : 74193 Item Name : Circuit Breaker FSC : 5925 Circuit Breakers
NSN : 5925-01-131-2137

You can send a request for quote for p/n AM3-2353-13 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Eaton Corporation (CAGE Code 74193). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925011312137. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with AM3-2353-13 part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Information for Part Number AM3-2353-13 with NSN 5925-01-131-2137, 5925011312137

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-131-2137

Item Description:

Circuit Breaker

59250113121370P
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
Am3-2353-13695

Characteristics Data of NSN 5925-01-131-2137, 5925011312137

MRCCriteriaCharacteristic
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AKPXPole Quantity3
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
CQXFInclosure Protection Type For Which DesignedHUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND SALT SPRAY PROOF
CPLMMaximum Continuous Load Current Rating Per Pole25.0 AMPERES AC ALL LOCATIONS
AFJNFragility FactorMODERATELY RUGGED
FREQFrequency In Hertz400.0 ALL LOCATIONS
AJWXMounting Surface To Terminal End Distance2.625 INCHES MAXIMUM
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 AC ALL LOCATIONS
CPRFOperating Voltage Type And Rating Per Pole In Volts250.0 AC ALL LOCATIONS
CPRJTrip Release MethodMAGNETIC ALL LOCATIONS
CQSMSwitch Location And Position DesignationINTERNAL AT POLE THREE
AEGJSwitch Contact ArrangementSINGLE POLE, DOUBLE THROW
AJECBoss Height0.150 INCHES NOMINAL
CPRLTrip Release CharacteristicTIME DELAY ALL LOCATIONS
CSSXSwitch Current Rating And Type In Amps10.0 AC AND 10.0 DC
CPRQReset MethodMANUAL
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 ALL LOCATIONS
CPRTManual Actuator Type And Quantity3 TOGGLE
TTQYTerminal Type And Quantity6 THREADED STUD
THSDThread Series DesignatorUNC
CPRYExternal Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
ADATBody Width2.265 INCHES MAXIMUM
CPSMInternal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
CPRWActuator FunctionTRIP-RESET
ADTVCase MaterialPLASTIC
CPRXActuator Position DesignationAT EACH POLE
CSWPSwitch Voltage Rating And Type In Volts250.0 AC AND 65.0 DC
AAJEThread Pitch Diameters+0.1177/+0.1214 INCHES
AXHRMounting Facility Type And Quantity6 THREADED HOLE
AAQLBody StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
CQJXNominal Thread Size0.138 INCHES
ADAQBody Length2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width0.750 INCHES NOMINAL
BBRJSpecial Handling FeatureMAGNETIC
AEBPCenter To Center Distance Between Terminals Parallel To Length1.940 INCHES NOMINAL
APNQArc Quenching MethodMAGNETIC BLOWOUT
PKWTUnpackaged Unit Weight11.100 OUNCES
AEBQCenter To Center Distance Between Terminals Parallel To Width0.750 INCHES NOMINAL
CMLPThread Quantity Per Inch32
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
CRTKSwitch Terminal TypeTAB, SOLDER LUG
CQWNTrip Delay Time In Seconds Per Rated Continuous Current2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS
AEBVUnthreaded Mounting Hole Diameter2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRZAuxiliary Switch Function And Quantity1 ALARM
MRCDecoded RequirementClear Text Reply
ASAP Semiconductor's Certifications and Memberships