JA3-Z-301-2 (Circuit Breaker) by Eaton Corporation - Request a Quote Now

Part No. : JA3-Z-301-2 Alternate P/N : JA3Z3012 Manufacturer : Eaton Corporation
CAGE Code : 74193 Item Name : Circuit Breaker FSC : 5925 Circuit Breakers
NSN : 5925-01-225-9333

You can send a request for quote for p/n JA3-Z-301-2 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Eaton Corporation (CAGE Code 74193). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925012259333. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with JA3-Z-301-2 part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Information for Part Number JA3-Z-301-2 with NSN 5925-01-225-9333, 5925012259333

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-225-9333

Item Description:

Circuit Breaker

59250122593330P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
Ja3-Z-301-2595

Characteristics Data of NSN 5925-01-225-9333, 5925012259333

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ABXDBUSHING LENGTH0.130 INCHES NOMINAL
ADAQBODY LENGTH2.000 INCHES NOMINAL
ADATBODY WIDTH2.250 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.531 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.750 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.656 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.898 INCHES NOMINAL
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CBBLFEATURES PROVIDEDHIGH INRUSH PROTECTION
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE25.0 AMPERES AC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE25.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES AC THIRD LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS THIRD LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY FIRST LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SECOND LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP THIRD LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FIRST LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SECOND LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
FEATSPECIAL FEATURESRELAY COIL HAS A SPECIAL ELECTRICAL SHORT FOR MECHANICAL TRIP
FREQFREQUENCY IN HERTZ50.0 OR 60.0 ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY6 SCREW