Part No. : 5925009829657 | Manufacturer : Eca Etablissement | CAGE Code : SCY13 |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers | NSN : 5925-00-982-9657 |
You can send a request for quote for p/n 5925009829657 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Eca Etablissement (CAGE Code SCY13). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925009829657. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 5925009829657 part requirements.
Required fields compulsory *
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | SANDTIGHT AND |
AKPX | Pole Quantity | 1 |
AAQL | Body Style | SINGLE POLE TYPE |
CQXF | Inclosure Protection Type For Which Designed | SHOCKPROOF |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
PKWT | Unpackaged Unit Weight | 1.500 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
ABXD | Bushing Length | 0.250 INCHES NOMINAL |
AEFQ | Nonturn Device Length | 0.078 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC AND |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC AND |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
AEFP | Nonturn Device Radius | 0.388 INCHES NOMINAL |
ADAT | Body Width | 0.562 INCHES MAXIMUM |
AEFR | Nonturn Device Width | 0.110 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
ADTV | Case Material | PLASTIC |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRX | Actuator Position Designation | AT POLE ONE |
CQJX | Nominal Thread Size | 0.438 INCHES |
ADAQ | Body Length | 0.750 INCHES MAXIMUM |
AEFN | Nonturn Device Location | AT 12 OCLOCK |
THSD | Thread Series Designator | UN |
AJWX | Mounting Surface To Terminal End Distance | 1.707 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
APNQ | Arc Quenching Method | AIR |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.703 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | CORROSION RESISTANT AND |
Please contact us to receive an instant quotation