Part No. : 27160 | Manufacturer : Electronic Transformer Corp | CAGE Code : 72149 |
Item Name : Transformer Power | NSN : 5950-00-521-8219 |
You can send a request for quote for p/n 27160 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Electronic Transformer Corp (CAGE Code 72149). The description of it is Transformer Power. The national stock number associated with this part is NSN 5950005218219. This part belongs to FSC part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 27160 part requirements.
Required fields compulsory *
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 9.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 5.719 INCHES NOMINAL |
ADAU | BODY HEIGHT | 7.750 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 81.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 500.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 6.20 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
FEAT | SPECIAL FEATURES | PRIMARY WINDING TAPPED TO ALTER OUTPUT VOLTAGE |
TTQY | TERMINAL TYPE AND QUANTITY | 7 THREADED STUD |