S1532392 (Circuit Breaker) by Ge Medical Systems - Request a Quote Now

Part No. : S1532392 Manufacturer : Ge Medical Systems CAGE Code : F0179
Item Name : Circuit Breaker FSC : 5925 Circuit Breakers NSN : 5925-00-159-0444

You can send a request for quote for p/n S1532392 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Ge Medical Systems (CAGE Code F0179). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925001590444. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with S1532392 part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Characteristics Data of NSN 5925-00-159-0444, 5925001590444

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH6.000 INCHES NOMINAL
ABKWOVERALL HEIGHT3.969 INCHES NOMINAL
ABMKOVERALL WIDTH4.125 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL
AKPXPOLE QUANTITY3
APNQIII ARC QUENCHING METHODDEION
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC ALL LOCATIONS AND 15.0 AMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS AND 125.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC ALL LOCATIONS AND 5000.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODTHERMAL ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRPULTIMATE TRIP TIME PER POLE IN SECONDS210.000 MINIMUM ALL LOCATIONS AND 4200.000 MAXIMUM ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP W/SEPARATE RESET
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT210.000 MINIMUM AT 125 PCT ALL LOCATIONS AND 4200.000 MAXIMUM AT 125 PCT ALL LOCATIONS AND 20.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 105.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 8.000 MINIMUM AT 300 PCT ALL LOCATIONS AND 23.000 MAXIMUM AT
CRCFTRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
FEATSPECIAL FEATURESMTG HOLES IN 2 ROWS OF 3,1.375 BY 4.844 IN. C TO C
TTQYTERMINAL TYPE AND QUANTITY6 SCREW
ASAP Semiconductor's Certifications and Memberships