Part No. : 99F1-1-2DT | Alternate P/N : 99F112DT | Manufacturer : Pentair Pump Group Inc |
CAGE Code : 10613 | Item Name : Pump Unit Centrifugal | FSC : 4320 Power AND Hand Pumps |
NSN : 4320-00-421-4318 |
You can send a request for quote for p/n 99F1-1-2DT to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Pentair Pump Group Inc (CAGE Code 10613). The description of it is Pump Unit Centrifugal. The national stock number associated with this part is NSN 4320004214318. This part belongs to FSC Power AND Hand Pumps part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 99F1-1-2DT part requirements.
Required fields compulsory *
MRC | Criteria | Characteristic |
---|---|---|
AHYX | Total Head | 214.500 FEET AND 214.500 FEET |
ELEC | Voltage In Volts | 440 |
AAYT | Intake Connection Quantity | 2 |
AHYW | Discharge Pressure | 100.0 POUNDS PER SQUARE INCH GAGE AND 100.0 POUNDS PER SQUARE INCH GAGE |
AHZS | Operation Relationship Design | SIMULTANEOUS |
AHYZ | Operating Speed At Rated Capacity | 3560.0 REVOLUTIONS PER MINUTE |
AHYV | Maximum Discharge Flow Rate | 80.0 GALLONS PER MINUTE AND 80.0 GALLONS PER MINUTE |
ACKL | Media For Which Designed | ETHYLENE GLYCOL |
AHZF | Centrifugal Pump Impeller Quantity | 2 |
AHZA | Pumping Element Operating Position | HORIZONTAL |
AAXS | Prime Mover Cooling Medium | AIR |
AHZE | Centrifugal Pump Design | RADIAL FLOW |
AJAF | Unpackaged Unit Length | 33.800 INCHES NOMINAL |
AKNA | Inclosure Type | FULLY INCLOSED |
AJAG | Unpackaged Unit Width | 17.7000 INCHES NOMINAL |
AJAH | Unpackaged Unit Height | 15.700 INCHES NOMINAL |
FREQ | Frequency In Hertz | 60 |
AAXH | Prime Mover Quantity | 2 |
FAAZ | Phase | THREE |
ACDC | Current Type | AC |
CSYL | Prime Mover Power Rating | 20.000 HORSEPOWER |
AENC | Pump Quantity | 2 |
MRC | Decoded Requirement | Clear Text Reply |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AAYV | Discharge Connection Quantity | 2 |
AAXX | Mounting Type | BASE |
AAYD | Stage Quantity | 1 |
AENK | Cooling Method | SELF VENTILATED |
AMPS | Current Rating In Amps | 25 |
ADZC | Environmental Protection | SUBMERSIBLE |
Please contact us to receive an instant quotation