Part No. : IUGN66-1-71-30.0 | Alternate P/N : IUGN66171300 | Manufacturer : Sensata Technologies Inc |
CAGE Code : 81541 | Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
NSN : 5925-01-659-1528 |
You can send a request for quote for p/n IUGN66-1-71-30.0 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Sensata Technologies Inc (CAGE Code 81541). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925016591528. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with IUGN66-1-71-30.0 part requirements.
Required fields compulsory *
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-659-1528 Item Description: Circuit Breaker | 5925 | 016591528 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Iugn66-1-71-30.0 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.0 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.515 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.530 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
AGAV | III END ITEM IDENTIFICATION | BOAT, WORK |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.256 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 PLUG-IN |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 80.0 DC SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL OVERLOAD ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.440 MINIMUM AT 125 PCT AND 10.0 MAXIMUM AT 125 PCT ALL LOCATIONS |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | CIRCUIT BREAKER |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |