Part No. : AP112-1-62-502 | Alternate P/N : AP112162502 | Manufacturer : Sensata Technologies Inc |
CAGE Code : 81541 | Item Name : Circuit Breaker | NSN : 5925-01-576-1576 |
You can send a request for quote for p/n AP112-1-62-502 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Sensata Technologies Inc (CAGE Code 81541). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925015761576. This part belongs to FSC part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with AP112-1-62-502 part requirements.
Required fields compulsory *
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-576-1576 Item Description: Circuit Breaker | 5925 | 015761576 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ap112-1-62-502 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
THSD | THREAD SERIES DESIGNATOR | UNEF |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | MAGNETIC CIRCUIT PROTECTOR |
AGAV | III END ITEM IDENTIFICATION | AN/BLQ 10A (V) 1 SYSTEM |
CMLP | THREAD QUANTITY PER INCH | 32 |
AKPX | POLE QUANTITY | 3 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC ALL LOCATIONS |
ADAT | BODY WIDTH | 1.937 INCHES MAXIMUM |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES MAXIMUM |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | III SPECIAL HANDLING FEATURE | MAGNETIC |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.828 INCHES MAXIMUM |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |
ADTV | CASE MATERIAL | METAL |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.550 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
Please contact us to receive an instant quotation