Part No. : 20 20410 | Alternate P/N : 2020410 | Manufacturer : Thales Australia Joint Systems |
CAGE Code : Z7E81 | Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
NSN : 5925-01-576-9218 |
You can send a request for quote for p/n 20 20410 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Thales Australia Joint Systems (CAGE Code Z7E81). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925015769218. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with 20 20410 part requirements.
Required fields compulsory *
MRC | Criteria | Characteristic |
---|---|---|
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CQQR | THREAD PITCH IN MILLIMETERS | 0.50 |
CQJX | NOMINAL THREAD SIZE | 3.0 MILLIMETERS |
AKPX | POLE QUANTITY | 2 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS |
ADAT | BODY WIDTH | 1.515 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 ALL LOCATIONS |
AJEC | BOSS HEIGHT | 0.130 INCHES NOMINAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB W/SCREW |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
THSD | THREAD SERIES DESIGNATOR | ISO M |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT AND 150.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.530 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.032 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.660 INCHES NOMINAL |
Please contact us to receive an instant quotation