HM2-B3-5-50DC-2 (Circuit Breaker) by Eaton Corporation - Request a Quote Now

Part No. : HM2-B3-5-50DC-2 Alternate P/N : HM2B3550DC2 Manufacturer : Eaton Corporation
CAGE Code : 74193 Item Name : Circuit Breaker FSC : 5925 Circuit Breakers
NSN : 5925-00-759-0906

You can send a request for quote for p/n HM2-B3-5-50DC-2 to ASAP Semiconductor using justpartsunlimited.com. This part is manufactured by Eaton Corporation (CAGE Code 74193). The description of it is Circuit Breaker. The national stock number associated with this part is NSN 5925007590906. This part belongs to FSC Circuit Breakers part family. An associate from ASAP Semiconductor will respond within 15 minutes to your query. It is our pleasure to help you with HM2-B3-5-50DC-2 part requirements.

Required fields compulsory *

Contact Information

Note: We will not share your information to any third parties.

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms & Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.

  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Information for Part Number HM2-B3-5-50DC-2 with NSN 5925-00-759-0906, 5925007590906

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-759-0906

Item Description:

Circuit Breaker

59250075909060P
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
Hm2-B3-5-50dc-2293

Characteristics Data of NSN 5925-00-759-0906, 5925007590906

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ABXDBUSHING LENGTH0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
ADAQBODY LENGTH1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM
ADATBODY WIDTH1.271 INCHES MINIMUM AND 1.291 INCHES MAXIMUM
ADTVCASE MATERIALMETAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING W/PANEL SEAL
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES DC ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.375 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.120 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.750 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITY4 WIRE HOOK
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.690 INCHES MINIMUM AND 1.710 INCHES MAXIMUM
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS50.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS500.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
ASAP Semiconductor's Certifications and Memberships