For competitive procurement options on part number W92-X112-1 from Tyco Electronics Corporation (CAGE Code 77342), look no further than Just Parts Unlimited. With the form presented on this page, you can submit information on your needs to receive tailored procurement solutions from our staff.
Part Number W92-X112-1 Details:
Part number W92-X112-1 is manufactured by Tyco Electronics Corporation and listed with the item name Circuit Breaker. Classified under NSN 5925-01-520-8619, the NIIN of this item is 015208619, its INC is 00136, and its NCB code is 01 (USA).
For organization and identification purposes, this item is listed within the Federal Supply Group (FSG) 59 Electrical and Electronic Equipment Components and Class (FSC) 5925 Circuit Breakers. These details are important for confirming parts before making a purchase.
Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.
How to Get Started on Procurement
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-520-8619 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015208619 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
W92-X112-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
BBRJ | Special Handling Feature | MAGNETIC |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
ADAT | Body Width | 1.500 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.471 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
THSD | Thread Series Designator | UNC |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CMLP | Thread Quantity Per Inch | 32 |
Guaranteed on-time delivery. |
|
Over 5100 manufacturers |
|
Customized and user-friendly database |
|
Complete purchasing solutions |
Thank You for Visiting! You Can Download the ASAP Semiconductor App On the Google Play Store and App Store to Get Updates On All of Our Latest Deals and Newest Parts.
Request for Quote